Lung Cancer
Volume 69, Issue 1 , Pages 71-76, July 2010

Quantitative helical dynamic contrast enhanced computed tomography assessment of the spatial variation in whole tumour blood volume with radiotherapy in lung cancer

  • Quan-Sing Ng

      Affiliations

    • National Cancer Centre, Singapore
    • Mount Vernon Cancer Centre, Northwood, United Kingdom
  • ,
  • Vicky Goh

      Affiliations

    • Paul Strickland Scanner Centre, Mount Vernon Hospital, Northwood, Middlesex HA6 2RN,United Kingdom
    • Corresponding Author InformationCorresponding author. Tel.: +44 1923 844 751; fax: +44 1923 844 600.
  • ,
  • Jessica Milner

      Affiliations

    • Mount Vernon Cancer Centre, Northwood, United Kingdom
  • ,
  • Josefin Sundin

      Affiliations

    • University of Hertfordshire, United Kingdom
  • ,
  • David Wellsted

      Affiliations

    • University of Hertfordshire, United Kingdom
  • ,
  • Michele I. Saunders

      Affiliations

    • Mount Vernon Cancer Centre, Northwood, United Kingdom
  • ,
  • Peter J. Hoskin

      Affiliations

    • Mount Vernon Cancer Centre, Northwood, United Kingdom

Received 23 February 2009; received in revised form 27 August 2009; accepted 1 September 2009. published online 25 September 2009.

Abstract 

We aim to assess the spatial distribution of blood volume (BV) in whole lung tumours in patients undergoing radiotherapy using helical dynamic contrast enhanced computed tomography (DCE-CT), and to determine whether conventional single level, or whole tumour measurements is more representative of the vascular effects of radiotherapy. Following ethical approval and informed consent, 15 patients with histologically proven non-small cell lung cancer underwent paired helical DCE-CT studies at baseline to assess repeatability, and after two fractions of radiotherapy (9Gy total dose). Tumour BV was calculated for individual contiguous 10mm axial slices, and for the entire tumour volume on a pixel-per-pixel basis. Baseline tumour BV was heterogeneous varying by 15.33%±17.11 between adjacent 10mm axial slices. Within subject coefficient of variation was 36.72% with conventional single tumour level evaluation, and 13.62% with whole tumour measurements. Following radiotherapy, one patient had an increase in BV greater than baseline variation (derived from the 95% limits of change) using single level evaluation; in contrast, seven patients had an increase in BV when the whole tumour was assessed. As a group, following radiotherapy, mean BV increased by 17.27% (paired t-test, p=0.20) with single level evaluation and 19.26% (p=0.049) with whole tumour assessment. Tumour BV measured using DCE-CT is spatially heterogeneous. Given the slice-by-slice variation in blood volume, our results demonstrate that whole tumour DCE-CT measurements are more repeatable, and may be a better predictor of vascular changes following therapy, compared to conventional single tumour level evaluations.

Keywords: Non-small cell lung cancer, Functional imaging, Perfusion computed tomography, Dynamic contrast enhanced computed tomography, Radiotherapy, Tumour angiogenesis, Measurement reproducibility

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0169-5002(09)00486-3

doi:10.1016/j.lungcan.2009.09.002

Lung Cancer
Volume 69, Issue 1 , Pages 71-76, July 2010